In sending a command, firstly send header that defined as 3 characters. Secondly formatting and send each argument.
Before sending a command, client must convert binary-expression to ascii-expression. (If the client sending a command without conversion, PLEN's moving is different from you intended.)
No differences the command line made of upper case or lower case.
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
DEVICE_ID | Set a device id. | 0 | 23 | 0 padding,hex,2byte |
VALUE | Set to apply native value. | -2048 | 2047 | 0 padding,hex,3byte |
example:
If you want to apply 1000 to device 10, send command below.
$an0a3e8
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
DEVICE_ID | Set a device id. | 0 | 23 | 0 padding,hex,2byte |
VALUE | Set to apply diff value. | -2048 | 2047 | 0 padding,hex,3byte |
example:
If you want to apply home value - 100 to device 4, send command below.
$ad04f9c
Attention!
You could also use "$MP", but this is deprecated.
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
SLOT | Set to read slot. | 0 | 89 | 0 padding,hex,2byte |
example:
If you want to play slot 4, send command below.
$pm04
Attention!
You could also use "$MS", but this is deprecated.
example:
If you want to stop a motion, send command below.
$sm
example:
If you want to apply home position, send command below.
$hp
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
SLOT | Set to read slot. | 0 | 89 | 0 padding,hex,2byte |
LOOP_COUNT | Set number of play. | 0 | 255 | 0 padding,hex,2byte |
example:
If you want to push function that plays slot 10 three times, send command below.
#pu0a03
example:
If you want to pop a function, send command below.
#po
example:
If you want to reset the interpreter, send command below.
#ri
Attention!
This is deprecated. Obsolescent at firmware version 2.x.
Please using >MH and >MF that are described after basically.
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
SLOT | Set to write slot. | 0 | 89 | 0 padding,hex,2byte |
NAME | Set a motion name. | --- | --- | white space padding,20byte |
FUNC | Set a function. (*1) | 0 | 255 | 0 padding,hex,2byte |
ARG0 | Set a function's arg 0. (*1) | 0 | 255 | 0 padding,hex,2byte |
ARG1 | Set a function's arg 1. (*1) | 0 | 255 | 0 padding,hex,2byte |
FRAME_LENGTH | Set a frame length. | 1 | 20 | 0 padding,hex,2byte |
TRANSITION_TIME_MS | Set a transition time (msec). | 32 | 65535 | 0 padding,hex,4byte |
VALUE[DEVICE_ID] | Set to apply value. (*2) | -32768 | 32767 | 0 padding,hex,4byte |
(*1) Type of function and role of args are described below.
"FUNC"'s Values | Roles |
---|---|
0 | --- |
1 | Play a motion with infinite loop between arg 0 and arg 1. |
2 | Jump to arg 0 if then stopped the motion. |
(*2) Sum of devices is 24 and all are servo motor.
example:
Let install a motion below.
Args | Values |
---|---|
SLOT | 0 |
NAME | Test |
FUNC | 0 |
ARG0 | 0 |
ARG1 | 0 |
FRAME_LENGTH | 2 |
TRANSITION_TIME_MS | 100 |
OUTPUT[EVEN] | 0 |
OUTPUT[ODD] | -1 |
Please send command below. (There are no CR, LF, or CRLF actually.)
>in
00Test 00000002
0064
0000ffff0000ffff0000ffff0000ffff
0000ffff0000ffff0000ffff0000ffff
0000ffff0000ffff0000ffff0000ffff
0064
0000ffff0000ffff0000ffff0000ffff
0000ffff0000ffff0000ffff0000ffff
0000ffff0000ffff0000ffff0000ffff
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
SLOT | Set to write slot. | 0 | 89 | 0 padding,hex,2byte |
NAME | Set a motion name. | --- | --- | white space padding,20byte |
FUNC | Set a function. (*1) | 0 | 255 | 0 padding,hex,2byte |
ARG0 | Set a function's arg 0. (*1) | 0 | 255 | 0 padding,hex,2byte |
ARG1 | Set a function's arg 1. (*1) | 0 | 255 | 0 padding,hex,2byte |
FRAME_LENGTH | Set a frame length | 1 | 20 | 0 padding,hex,2byte |
Please get more detail at ">IN" section.
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
SLOT | Set to write slot. | 0 | 89 | 0 padding,hex,2byte |
FRAME_ID | Set a frame id. | 1 | 20 | 0 padding,hex,2byte |
TRANSITION_TIME_MS | Set a transition time (msec). | 32 | 65535 | 0 padding,hex,4byte |
VALUE[DEVICE_ID] | Set to apply value. (*2) | -32768 | 32767 | 0 padding,hex,4byte |
Please get more detail at ">IN" section.
example:
If you want to reset the joint settings, send command below.
>js
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
DEVICE_ID | Set a device id. | 0 | 23 | 0 padding,hex,2byte |
VALUE | Set to apply home value. | -2048 | 2047 | 0 padding,hex,3byte |
example:
If you want to apply 100 as home value to device 0, send command below.
>ho00064
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
DEVICE_ID | Set a device id. | 0 | 23 | 0 padding,hex,2byte |
VALUE | Set to apply max value. | -2048 | 2047 | 0 padding,hex,3byte |
example:
If you want to apply 100 as max value to device 0, send command below.
>ma00064
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
DEVICE_ID | Set a device id. | 0 | 23 | 0 padding,hex,2byte |
VALUE | Set to apply min value. | -2048 | 2047 | 0 padding,hex,3byte |
example:
If you want to apply -1 as min value to device 10, send command below.
>mi0afff
example:
If you want to dump the joint settings, send command below.
<js
At that time, outputting result like json below.
[
{
"max": <integer>,
"min": <integer>,
"home": <integer>
},
...
]
Args | Roles | Min (dec) | Max (dec) | Format |
---|---|---|---|---|
SLOT | Set to read slot. | 0 | 89 | 0 padding,hex,2byte |
example:
If you want to dump slot 0, send command below.
<mo00
At that time, outputting result like "motion.json". (See also...) However, property "device"'s type is not string but integer defined as device id in "device_map.json".
example:
If you want to dump the version information, send command below.
<vi
At that time, outputting result like json below.
{
"device": <string>,
"codename": <string>,
"version": <string>
}